Zum Ende der Metadaten springen
Zum Anfang der Metadaten

Sie zeigen eine alte Version dieser Seite an. Zeigen Sie die aktuelle Version an.

Unterschiede anzeigen Seitenhistorie anzeigen

« Vorherige Version anzeigen Version 3 Nächste Version anzeigen »

As an additional power consumer it is possible to add one or more charging stations.


The first field can be used to name the charging station. 

Count sets the amount of how many charging stations are used. 


The total charging power is  calculated by multiplying the charging capacity per charging station and the number. 

Charging capacity per charging station in kW * Number of charging stations


The total power demand is calculated from the total charging power and the specified charging period multiplied by 365 days. It is assumed that the power is distributed evenly over all specified hours. 

365 days * specified charging period in hours * charging power per charging station in kW * number of charging stations

  • Keine Stichwörter