As an additional power consumer it is possible to add one or more charging stations.


The first field can be used to name the charging station. 

Count sets the amount of how many charging stations are used. 


The total charging power is  calculated by multiplying the charging capacity per charging station and the number. 

Info

Charging capacity per charging station in kW * Number of charging stations


The total power demand is calculated from the total charging power and the specified charging period multiplied by 365 days. It is assumed that the power is distributed evenly over all specified hours. 

Info

365 days * total power demand = a • b • c • d
where 
a = 365 days,
b=specified charging period in hours * ,
c=charging power per charging station in kW *
d=number of charging stations