  • Shut-off temperature - only in case of mono energy partial parallel operation mode
  • Hysteresis - temperature difference between switching the heat pump on and off
  • Cooling function - With suitable heat pump: May the heat pump cool?

Image RemovedImage Added

Buffer storage

...

  • Solar thermal can be added/removed.
  • Domestic hot water temperature - the temperature to which the domestic hot water storage tank should be maintained at the level of the draw-off pipes. When the circulation is activated, the temperature of domestic hot water should be at least 60°C to prevent the formation of legionella
  • Thermal disinfection - setting whether and at what intervals thermal disinfection of the storage tank should be performed. The storage tank is then heated to 75°C for 5 minutes to prevent the formation of legionella and other bacteria
  • Loading time: Here you can set in quarter-hourly resolution when the drinking water tank can be loaded (left mouse button on, right mouse button off)
  • Circulation - define the properties of the circulation network to calculate the heat loss. The heat loss per day is distributed evenly throughout the day

Image RemovedImage Added


Distributions

  • Depending on the selection of components, an overflow valve or a flow reduction can be selected for the distribution, only the rearmost distribution is fixed.

...