- Shut-off temperature - only in case of mono energy partial parallel operation mode
- Hysteresis - temperature difference between switching the heat pump on and off
- Cooling function - With suitable heat pump: May the heat pump cool?
Buffer storage
...
- Solar thermal can be added/removed.
- Domestic hot water temperature - the temperature to which the domestic hot water storage tank should be maintained at the level of the draw-off pipes. When the circulation is activated, the temperature of domestic hot water should be at least 60°C to prevent the formation of legionella
- Thermal disinfection - setting whether and at what intervals thermal disinfection of the storage tank should be performed. The storage tank is then heated to 75°C for 5 minutes to prevent the formation of legionella and other bacteria
- Loading time: Here you can set in quarter-hourly resolution when the drinking water tank can be loaded (left mouse button on, right mouse button off)
- Circulation - define the properties of the circulation network to calculate the heat loss. The heat loss per day is distributed evenly throughout the day
Distributions
- Depending on the selection of components, an overflow valve or a flow reduction can be selected for the distribution, only the rearmost distribution is fixed.
...